Description: Power Quality Meter 3-Phase 4-Wire Power Quality Analyzer with Range 0.10A-100A Introduction of Power quality analyzer:Power Quality Analyzer is a comprehensive test instrument carefully developed by our company and specially designed for field test of three phases, multi-functional and intelligent, concise man-machine operation. It is easy to use, large LCD screen display, high resolution, interface in both Chinese and English, shock-proof shell structure and so on. Can simultaneously measure the 4-channel current (ABC three phase and neutral wire current), 4-channel voltage (ABC three-phase voltage and neutral line voltage to ground), the peak value of current voltage, maximum/minimum value over a period, three-phase imbalance factor, short-time voltage flicker, transformer K factor, active power, reactive power, apparent power, power factor and displacement power factor, active power, reactive power, apparent power, total harmonic distortion and harmonic, etc; Display real-time waveform, harmonic ratio bar charts of current voltage; Dynamically capture instantaneous change of voltage current, monitoring starting current, monitoring the power parameters and generate the alarm list, generate the trend chart for a long time record test data.In the current power applications, more and more large power equipment, power grid fault have become more and more complex, with development of the industry, it put forward high request more and more to quality that electric energy. We provide this power quality analyzer for that, which you can troubleshoot of complex power system more quickly and accurate, and monitoring and maintenance of power quality parameters more comprehensive and systemic.Power quality analyzer adopt DSP + ARM double processor architecture, DSP is use for data collection and the processing of algorithm, the ARM is use for the communication protocol and the man-machine interface processing; Analog signal acquisition is by 2 pieces ADC Chip of ADI company. Resolution for ADC Chip is 16 bit and it is 4 channel synchronous sampling. The highest sampling rate can reach 1 MSPS, to ensure the accuracy of the channel and the information integrity, and wouldn’t miss any transient changes in the grid, can more accurate to detect the transient waveform rising and dropping drastically, and waveform instantaneous interrupt; DSP working frequency is over 200 MHZ, to be able to timely monitoring of the power grid and dynamically adjust the sampling frequency to realize synchronization of power frequency and sampling frequency; Using a 5.6 -inch LCD color screen display, a resolution of 640 dots x 480 dots, with different display color difference between the parameters of phase, waveform, vector diagram, harmonic ratio, the user can be more efficient and more intuitive understand the state of power grid parameters. Built-in flash memory can store 60 group of screenshots at the same time, 150 groups of capture transient voltage/current waveform figure, and 12800 groups of alarm list. Starting current detection model can continuously capture starting current waveform for 100 s. Built-in 2G memory card to store the trend curve record, simultaneous recording 20 parameters (can choose according to need) collect data for once every five seconds, trend curve records can be stored for 300 days.Power Quality Analyzer also named: Intelligent Three Phase Power Quality Analyzer, Multifunctional Power Quality Analyzer, which simultaneous with the functions of harmonic Analyzer, phase volt-ampere meter, electric parameter tester. It apply to electricity industry, petrochemical, metallurgy, railway, mining enterprises, scientific research institution, metrology department. Especially suitable for comprehensive analysis and diagnosis on all the voltage, current, power, power, harmonic, phase electric parameters. Introduction of Clamp Current Sensor:Clamp current sensor is a high-precision AC current convertor. It adopts a clamp-shaped structure. It can be quickly and easily accessed and used. The compact size is easier to carry and use. Applicable to AC current, leakage current, high harmonic current, phase, electric energy, power, power factor and other tests.It can be used with a variety of measuring instruments, such as: Field calibrator for watt-hour meter, multi-function energy meter, oscillometer, digital multimeter, electrical identification device, cable fault detector, dual-clamp phase volt-ampere meter, digital current recorder, etc., can measure and compare a variety of electrical parameters under constant power. Widely used in substations, power plants, industrial and mining enterprises and testing stations, electrical maintenance departments for current detection and field electrical work, etc. Specifications: Power supplyRechargeable lithium-ion battery packs 9.6V, backup charger.Battery indicatorBattery symbol shows dump energy. When the voltage is too low, automatic shutdown after the 1 minute.Power consumptionCurrent consumption of normal test 490 mA, continuous working for 10 hours.Display modeLCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm.Size of clampSmall sharp current clamp: 20mm×20mm;Instrument dimensionsL×W×H: 277.2mm ×227.5mm ×153mm.Number of channels4U/4I.Phase-to phase voltage1.0V~2000V.Phase-to-neutral voltage1.0V~1000V.CurrentCurrent clamp: 0.10A~100A;Frequency40Hz~70Hz.Parameters of electricityW, VA, Var, PF, DPF, cosφ, tanφ.Energy parametersWh, Varh, Vah.HarmonicOrder 0~50.Total harmonic distortionOrder 0~50, each phase.Expert modeYes.Number of Transient records150 sets.Voltage flickerYes.Starting current modeYes, 100 seconds.3 phases unbalanceYes.Record300 days(simultaneous recording 20 parameters, record one point every 5 seconds).Min/Max recorded valueMeasurement of maximum and minimum values over a period of time.Alarm40 different types of parameter selections, 12,800 sets alarm logs.PeakYes.Phasor diagram displayAutomatically.Capacity of snapshots60.Menu languageEnglish/Chinese.CommunicationUSB.Automatic switching offWhen an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device is not automatic switching off.In other test mode, 15 minutes without keystrokes, automatic shutdown after prompt 1 minute.Backlight functionYes, suitable for use at night and dark place.WeightHost: 1.6kg (with battery).circle current clamp: 252g×4;Test wires and power adapter: 800g;Total weight: about 10.8kg (with packaging).Length of voltage test wire3m.Length of current sensor wire2m.Working temperature and humidity-10°C~40°C; below 80%Rh.Storage temperature and humidity-10°C~60°C; below 70%Rh.Input impedanceInput impedance of test voltage: 1MΩ.Withstand voltageWithstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell.InsulationBetween instrument wiring and shell ≥10MΩ.StructureDouble insulation, with insulation vibration-proof sheath.Safely rulesIEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2.
Price: 2510 USD
Location: 合肥
End Time: 2024-12-14T02:42:52.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Phase-to-neutral voltage: 1.0V~1000V
Energy parameters: Wh, Varh, Vah
Phase-to phase voltage: 1.0V~2000V
Parameters of electricity: W, VA, Var, PF, DPF, cosφ, tanφ.
MPN: 202410140940
Size of clamp: Circle current clamp: 20mm×20mm
Power supply: Rechargeable lithium-ion battery packs 9.6V, backup charger
Weight: 10kg
Number of Transient records: 150 sets
Brand: VTSYIQI
Phase Configuration: 3-Phase
Length of current sensor wire: 2m
Frequency: 40Hz~70Hz
Instrument dimensions: L×W×H: 277.2mm × 227.5mm × 153mm
Country/Region of Manufacture: China
Current: Current clamp: 0.10A~100A
Communication: USB
Length of voltage test wire: 3m