Description: NEW Siemens 6ES7 331-7KF02-0AB0 / 6ES7331-7KF02-0AB0 Product Description · NEW Siemens 6ES7 331-7KF02-0AB0 / 6ES7331-7KF02-0AB0 Product Specification: Supply voltage Load voltage L+ Rated value (DC) 24 V Reverse polarity protection Yes Input current from load voltage L+ (without load), max. 200 mA from backplane bus 5 V DC, max. 50 mA Power losses Power loss, typ. 1 W Analog inputs Number of analog inputs 8 Number of analog inputs for resistance measurement 4 permissible input voltage for voltage input (destruction limit), max. 20 V; continuous; 75 V for max. 1 s (mark to space ratio 1:20) permissible input current for current input (destruction limit), max. 40 mA Input ranges Voltage Yes Current Yes Thermocouple Yes Resistance thermometer Yes Resistance Yes Input ranges (rated values), voltages 0 to +10 V No 1 to 5 V Yes Input resistance (1 to 5 V) 100 kΩ 1 to 10 V No -1 V to +1 V Yes Input resistance (-1 V to +1 V) 10 MΩ -10 V to +10 V Yes Input resistance (-10 V to +10 V) 100 kΩ -2.5 V to +2.5 V Yes Input resistance (-2.5 V to +2.5 V) 100 kΩ -250 mV to +250 mV Yes Input resistance (-250 mV to +250 mV) 10 MΩ -5 V to +5 V Yes Input resistance (-5 V to +5 V) 100 kΩ -50 mV to +50 mV No -500 mV to +500 mV Yes Input resistance (-500 mV to +500 mV) 10 MΩ -80 mV to +80 mV Yes Input resistance (-80 mV to +80 mV) 10 MΩ Input ranges (rated values), currents 0 to 20 mA Yes Input resistance (0 to 20 mA) 25 Ω -10 to +10 mA Yes Input resistance (-10 to +10 mA) 25 Ω -20 to +20 mA Yes Input resistance (-20 to +20 mA) 25 Ω -3.2 to +3.2 mA Yes Input resistance (-3.2 to +3.2 mA) 25 Ω 4 to 20 mA Yes Input resistance (4 to 20 mA) 25 Ω Input ranges (rated values), thermoelements Type B No Type E Yes Input resistance (Type E) 10 MΩ Type J Yes Input resistance (type J) 10 MΩ Type K Yes Input resistance (Type K) 10 MΩ Type L Yes Input resistance (Type L) 10 MΩ Type N Yes Input resistance (Type N) 10 MΩ Type R No Type S No Type T No Type U No Type TXK/TXK(L) to GOST No Input ranges (rated values), resistance thermometers Cu 10 No Ni 100 Yes; Standard Input resistance (Ni 100) 10 MΩ Ni 1000 No LG-Ni 1000 No Ni 120 No Ni 200 No Ni 500 No Pt 100 Yes; Standard Input resistance (Pt 100) 10 MΩ Pt 1000 No Pt 200 No Pt 500 No Input ranges (rated values), resistors 0 to 150 ohms Yes Input resistance (0 to 150 ohms) 10 MΩ 0 to 300 ohms Yes Input resistance (0 to 300 ohms) 10 MΩ 0 to 600 ohms Yes Input resistance (0 to 600 ohms) 10 MΩ 0 to 6000 ohms No Thermocouple (TC) Characteristic linearization for thermocouples Type E, J, K, L, N Temperature compensation Parameterizable Yes internal temperature compensation Yes external temperature compensation with compensations socket Yes Resistance thermometer (RTD) Characteristic linearization for resistance thermometer Pt100 (standard, climatic range), Ni100 (standard, climatic range) Characteristic linearization Parameterizable Yes Cable length Cable length, shielded, max. 200 m Analog value creation Measurement principle integrating Integrations and conversion time/resolution per channel Resolution with overrange (bit including sign), max. 15 bit; Unipolar: 9/12/12/14 bits; bipolar: 9 bits + sign/12 bits + sign/12 bits + sign/14 bits + sign Integration time, parameterizable Yes; 2,5 / 16,67 / 20 / 100 ms Basic conversion time, ms 3 / 17 / 22 /102 ms Interference voltage suppression for interference frequency f1 in Hz 400 / 60 / 50 / 10 Hz Encoder Connection of signal encoders for current measurement as 2-wire transducer Yes for current measurement as 4-wire transducer Yes for resistance measurement with two-wire connection Yes for resistance measurement with three-wire connection Yes for resistance measurement with four-wire connection Yes Errors/accuracies Operational limit in overall temperature range Voltage, relative to input area, (+/-) 1 %; +/-1% (80 mV); +/-0.6% (250 to 1000 mV); +/-0.8% (2.5 to 10 V) Current, relative to input area, (+/-) 0.7 %; From 3.2 to 20 mA Resistance, relative to input area, (+/-) 0.7 %; 150, 300, 600 Ohm Resistance thermometer, relative to input area, (+/-) 0.7 %; +/-0.7% (Pt100/ Ni100); +/-0.8% (Pt100 climate) Basic error limit (operational limit at 25 °C) Voltage, relative to input area, (+/-) 0.6 %; +/-0.4% (250 to 1000 mV); +/-0.6 % (2.5 to 10 mV); +/-0.7 % (80 mV) Current, relative to input area, (+/-) 0.5 %; 3.2 to 20 mA Resistance, relative to input area, (+/-) 0.5 %; 150, 300, 600 Ohm Resistance thermometer, relative to input area, (+/-) 0.6 %; +/-0.5% (Pt100/ Ni100); +/-0.6% (Pt100 climate) Isochronous mode Isochronous operation (application synchronized up to terminal) No Interrupts/diagnostics/status information Alarms Diagnostic alarm Yes; Parameterizable, channels 0 and 2 Limit value alarm Yes; Parameterizable Diagnostic messages Diagnostic functions Yes; Parameterizable Diagnostic information readable Yes Diagnostics Yes Diagnostics indication LED Group error SF (red) Yes Galvanic isolation Galvanic isolation analog inputs between the channels No between the channels and the backplane bus Yes Connection method required front connector 20-pin Dimensions Width 40 mm Height 125 mm Depth 120 mm Weights Weight, approx. 250 g Package content: 1 x Siemens 6ES7 331-7KF02-0AB0 / 6ES7331-7KF02-0AB0
Price: 181.16 USD
Location: Dayton, New Jersey
End Time: 2024-01-16T07:13:08.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money Back
Brand: Siemens
Model: 6ES7 331-7KF02-0AB0
MPN: 6ES7 331-7KF02-0AB0