Description: MainrangeTeSysproduct nameTeSys Dproduct or component typeContactordevice short nameLC1Dcontactor applicationMotor controlResistive loadutilisation categoryAC-3AC-1poles description3Ppower pole contact composition3 NO[Ue] rated operational voltagePower circuit <= 300 V DC 25...400 HzPower circuit <= 690 V AC[Ie] rated operational current125 A (at <60 °C) at <= 440 V AC AC-1 for power circuit80 A (at <60 °C) at <= 440 V AC AC-3 for power circuitmotor power kW22 kW 220...230 V AC 50/60 Hz37 kW 380...400 V AC 50/60 Hz45 kW 415...440 V AC 50/60 Hz55 kW 500 V AC 50/60 Hz45 kW 660...690 V AC 50/60 Hz45 kW 1000 V AC 50/60 Hzmotor power HP (UL / CSA)20 hp 200/208 V AC 50/60 Hz 3 phase7.5 hp at 115 V AC 50/60 Hz for 1 phase motors15 hp at 230/240 V AC 50/60 Hz for 1 phase motors25 hp at 230/240 V AC 50/60 Hz for 3 phases motors60 hp at 460/480 V AC 50/60 Hz for 3 phases motors60 hp at 575/600 V AC 50/60 Hz for 3 phases motorscontrol circuit typeAC at 50/60 Hz[Uc] control circuit voltage208 V AC 50/60 Hzauxiliary contact composition1 NO + 1 NC[Uimp] rated impulse withstand voltage8 kV conforming to IEC 60947overvoltage categoryIII[Ith] conventional free air thermal current10 A 140 °F (60 °C) signalling circuit125 A (at 60 °C) for power circuitIrms rated making capacity140 A AC signalling circuit IEC 60947-5-1250 A DC signalling circuit IEC 60947-5-11100 A at 440 V for power circuit conforming to IEC 60947rated breaking capacity1100 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current640 A 40 °C - 10 s for power circuit990 A 40 °C - 1 s for power circuit135 A 40 °C - 10 min for power circuit320 A 40 °C - 1 min for power circuit100 A - 1 s for signalling circuit120 A - 500 ms for signalling circuit140 A - 100 ms for signalling circuitassociated fuse rating10 A gG signalling circuit IEC 60947-5-1200 A gG at <= 690 V coordination type 1 for power circuit160 A gG at <= 690 V coordination type 2 for power circuitaverage impedance0.8 mOhm - Ith 125 A 50 Hz for power circuit[Ui] rated insulation voltagePower circuit 600 V CSAPower circuit 600 V ULPower circuit: 1000 V conforming to IEC 60947-4-1Signalling circuit 690 V IEC 60947-1Signalling circuit 600 V CSASignalling circuit 600 V ULelectrical durability0.8 Mcycles 125 A AC-1 at Ue <= 440 V1.5 Mcycles 80 A AC-3 at Ue <= 440 Vpower dissipation per pole5.1 W AC-312.5 W AC-1Front coverWithmounting supportRailPlatestandardsCSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certificationsGOSTDNVULCCCLROS (Lloyds register of shipping)BVCSAGLRINAconnections - terminalsControl circuit: lugs-ring terminals (external diameter: 8 mm)Power circuit bars 1 3 x 16 mmPower circuit lugs-ring terminals 0.67 in (17 mm))tightening torqueControl circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver flat Ø 6 mm M3.5Control circuit: 1.2 N.m - on lugs-ring terminals - with screwdriver Philips No 2 M3.5Power circuit 106.21 lbf.in (12 N.m) lugs-ring terminals flat Ø 8 mm M6Power circuit 106.21 lbf.in (12 N.m) lugs-ring terminals hexagonal 0.39 in (10 mm) M6Power circuit 106.21 lbf.in (12 N.m) bars flat Ø 8 mm M6Power circuit 106.21 lbf.in (12 N.m) bars hexagonal 0.39 in (10 mm) M6operating time20...35 ms closing6...20 ms openingsafety reliability levelB10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1mechanical durability4 Mcyclesmaximum operating rate3600 cyc/h 140 °F (60 °C)Complementarycoil technologyWithout built-in suppressor modulecontrol circuit voltage limits0.85...1.1 Uc (-40…55 °C):operational AC 60 Hz0.3...0.6 Uc -40…158 °F (-40…70 °C) drop-out AC 50/60 Hz0.8...1.1 Uc (-40…55 °C):operational AC 50 Hz1...1.1 Uc (55…70 °C):operational AC 50/60 Hzinrush power in VA245 VA 60 Hz cos phi 0.75 (at 20 °C)245 VA 50 Hz cos phi 0.75 (at 20 °C)hold-in power consumption in VA26 VA 60 Hz cos phi 0.3 (at 20 °C)26 VA 50 Hz cos phi 0.3 (at 20 °C)heat dissipation6…10 W at 50/60 Hzauxiliary contacts typetype mechanically linked 1 NO + 1 NC conforming to IEC 60947-5-1type mirror contact 1 NC conforming to IEC 60947-4-1signalling circuit frequency25...400 Hzminimum switching current5 mA signalling circuitminimum switching voltage17 V signalling circuitnon-overlap time1.5 ms on de-energisation between NC and NO contact1.5 ms on energisation between NC and NO contactinsulation resistance> 10 MOhm signalling circuitcontact compatibilityM11compatibility codeLC1DEnvironmentIP degree of protectionIP20 front face IEC 60529protective treatmentTH IEC 60068-2-30pollution degree3ambient air temperature for operation-40…60 °C60…70 °C with deratingambient air temperature for storage-76…176 °F (-60…80 °C)operating altitude0...3000 mfire resistance1562 °F (850 °C) IEC 60695-2-1flame retardanceV1 UL 94mechanical robustnessVibrations contactor open: 2 Gn, 5...300 HzShocks contactor open: 8 Gn for 11 msVibrations contactor closed: 3 Gn, 5...300 HzShocks contactor closed: 10 Gn for 11 msheight5.00 in (127 mm)Maximum Width3.35 in (85 mm)Maximum Depth5.12 in (130 mm)Net Weight3.51 lb(US) (1.59 kg) WH Box 133
Price: 329.97 USD
Location: Stevens, Pennsylvania
End Time: 2024-11-10T20:23:14.000Z
Shipping Cost: N/A USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Buyer
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Current Rating: 80 A
Country/Region of Manufacture: Czech Republic
Custom Bundle: No
Mounting Style: Panel Mount
Number of Poles: 3-Pole
MPN: LC1D806LE7
Brand: SQUARE D