Description: Veterinary Patient Monitor CMS6000VET Introduction The CMS6000VET Veterinary Monitor has abundant monitoring functions and can be used for monitoring of cat, dog and other animals. User may select different parameter configurations according to different requirements. It adopts 100-240V~,50/60Hz for power supply, 8'' TFT color LCD for displaying real-time data and waveform, and up to 8-channel waveform and all monitoring parameters can be displayed simultaneously. A 48mm thermal printer has equipped with the device. In addition, it can be connected to the central monitoring system via wired/wireless network so as to form a network monitoring system. This device can monitor such parameters as ECG, RESP, SpO2, PR, NIBP and dual- channel TEMP, etc. It integrates parameter measurement module, display and recorder in one device to form a compact and portable equipment. Functions Standard parameters: ECG, RESP, SpO2, PR, NIBP, dual-channel TEMP 1)ECG Heart rate(HR) ECG waveform Arrhythmia and ST-segment analysis 2)RESP Respiration rate(RR) Respiration waveform 3)SpO2 Oxygen saturation(SpO2) Plethysmogram(PLETH) waveform Pulse rate(PR) Bar graph 4)NIBP Systolic pressure(SYS), Diastolic pressure(DIA), Mean pressure(MEAN) 5)TEMP T1, T2, TD It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation, etc. Features 1)8'' TFT color LCD, multi-language interface(Simplified Chinese, Traditional Chinese, English, French, German, Turkish, Spanish, Portuguese, Italian, Dutch, Romanian, Russian, Kazakhstan, Polish, Czech). 2)Fanless design, quiet, energy-saving and clean, which reduces the possibility of cross-infection. 3)With standard interface, OxyCRG, trend chard, big character interface and view bed, convenient to observe. 4)Waveform, parameter color and location can be set optionally. 5)Operation mode: keys and buttons. 6)Display up to 8-channel waveform on one screen. 7)Display 7-lead ECG waveform on one screen, and with ECG step function. 8)Adopt digital SpO2 technology, anti-motion and anti-ambient light interference, and measurement can be performed under the circumstance of weak filling. 9)NIBP measurement mode: Manual/AUTO/STAT, storage for 4800-group NIBP data. 10)Review for 71 alarm events of all parameters and 60 arrhythmia alarm events. 11)Drug concentration calculation and titration table functions. 12)Print trend table data with one-key. 13)Connect to Central Monitoring System by 3G, WiFi or wired mode. 14)AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring. 15)Anti-high frequency surgical unit, defibrillation-proof(special leads are necessary). Performance ▲ECG Lead mode:3-lead or 5-lead Lead selection:I, II, III, aVR, aVL, aVF, V Waveform:5-lead, 2-channel 3-lead, 1-channel Gain:2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV, 40mm/mV Scan speed:12.5mm/s, 25 mm/s, 50 mm/s HR: Measurement and alarm range:15~350bpm Accuracy:±1% or ±1bpm, whichever is greater Alarm accuracy:± 2 bpm Resolution:1 bpm ST-segment monitoring: Measurement and alarm range: -2.0mV~+2.0mV Accuracy:-0.8mV~+0.8mV ±0.04mV or ±10%, whichever is greater Other range: unspecified Arrhythmia analysis: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC Pacemaker:yes ▲RESPIRATION Method:R-F(RA-LL) Impedance Respiration rate: Measurement and alarm range:0~150rpm Resolution:1 rpm Measurement accuracy:±2 rpm Alarm accuracy:±3 rpm Apnea alarm:10~40s Scan speed:6.25 mm/s, 12.5 mm/s, 25 mm/s ▲NIBP Method:Oscillometry Mode:Manual/AUTO/STAT Measurement interval in AUTO mode: 1/2/3/4/5/10/15/30/60/90/120/240/480/960 minutes Measurement period in STAT mode:5 minutes Measurement and alarm range:10 ~ 270 mmHg Resolution:1 mmHg Cuff pressure accuracy:±3 mmHg Measurement accuracy: Maximal mean error:±5 mmHg Maximal standard deviation:8mmHg Over-pressure protection: Other mode:297±3 mmHg Dog mode:240±3 mmHg Cat mode: 147±3 mmHg ▲SpO2 Measurement and alarm range:0 ~ 100% Resolution:1% Measurement accuracy:70%~100%: ±2%; 0%~69%: unspecified ▲PR Measurement and alarm range:30 ~ 250 bpm Measurement accuracy:±2 bpm or ±2%, whichever is greater ▲TEMP Channel:dual-channel Measurement and alarm range:0 ~ 50℃ Resolution:0.1 ℃ Accuracy:±0.1 ℃ ▲Power supply:100-240V~,50/60Hz ▲Safety classification:Class I, type CF defibrillation-proof applied part Accessories 1)Digital BD7 veterinary tongue-clip SpO2 sensor (1M) 2)General digital SpO2 sensor extension cable (2M) 3)Neonatal capsule single tube repeatable cuff (6-11cm) 4)NIBP extension tube 5)5-lead ECG lead cable (American-Standard) 6)ECG veterinary clip (*5) 7)Transvaginal TEMP probe 8)Power adapter 9)Power cord 10)User Manual Physical characteristic Dimension: 235 mm(L) × 141 mm(W) × 222 mm(H) Weight: 2.5 Kg
Price: 459 USD
Location: beijing
End Time: 2024-02-25T03:20:15.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 60 Days
Refund will be given as: Money Back
Brand: CONTEC
Screen Dimensions: 8'' TFT color LCD
Technology: Digital
Model: CMS6000-VET
MPN: Does Not Apply
Features: Battery Operated, Handheld
Monitor Parameters: Blood Pressure, Blood Pressure - NIBP, Blood Pressure - ABPM, ECG, O2 - SpO2, CO2, Temperature
Intended Use/Discipline: Veterinary Medicine