Description: Controller Functions and Settings 1. Main Interface Overview 1.1 Main Display Time Display: Shows the current date and time. Temperature and Humidity Display: Displays the ambient air temperature, relative humidity, and Vapor Pressure Deficit (VPD) data, which relies on an external temperature and humidity sensor connected to the controller. (Sensor Placement Recommendations) CO2 Display: Indicates the concentration of CO2 in the environment, which relies on an external CO2 sensor. Soil Data Display: Provides real-time soil temperature, humidity, and Electrical Conductivity (EC) readings when the soil sensor is connected, which relies on an external soil sensor. 1.2 Peripheral Interface Displays the connection status of up to five external devices. If a device is not connected to the controller, its status will be indicated as “offline.” 2. How to Control Led Grow Light (G Series/ SE Series/ SF Series) (Note: GGS 2-in-1 Adapter is required if the LED grow light needs to be controlled by the GGS Controller.) 2.1 Manual Mode Brightness can be manually adjusted from 0% (off) to 100% (full brightness). 2.2 Time Period Mode Start Time: Sets the time for the lights to turn on. End Time: Sets the time for the lights to turn off. Brightness: Allows adjustment of the brightness level when the lights are on. Go Dark: Configures a temperature threshold for dimming, where the lights will automatically reduce brightness when the ambient temperature reaches the set high-temperature threshold. Turn Off: Defines a temperature threshold for automatic shutdown, where the lights will turn off once the high-temperature protection threshold is reached. Sunrise/Sunset: Enables a sunrise/sunset simulation by gradually adjusting the brightness from dim to bright during sunrise and from bright to dim during sunset. 3. How to Control Clip Fan, Inline Fan, and Other Devices How to control Clip Fan & Inline FanIn the controller interface, the Fan (Clip Fan) and Blower (Inline Fan) sections are not yet available and will only support the next-generation Clip Fan and Inline Fan. If you already own or are considering purchasing our Clip Fan or Inline Fan, you may consider the GGS AC5 Power Strip(Coming soon, stay tuned!) as a solution. By plugging your devices into the GGS AC5 Power Strip(Coming soon, stay tuned!)and integrating the sensors installed on the Power Strip, you can still automate the operation of your equipment. (In this solution, the Clip Fan does not need to be connected to the "Fan" port on the GGS 2-in-1 adapter.)The Power Strip also supports connecting supplemental devices such as light bars, humidifiers, and more. 4. How to Control GGS Power Strip(Coming soon, stay tuned!) If you have both the GGS Controller Kits and the GGS AC5 Power Strip Kits, you can control the GGS AC5 Power Strip through the controller. 4.1 Manual Mode Controls the On/Off status of each outlet on the power strip. The 5-outlet model has 5 outlets, and the 10-outlet model has 10 outlets. 4.2 Time Period Mode Start Time: Set the time for the outlet to turn on. End Time: Set the time for the outlet to turn off. 4.3 Time Cycle Mode Start time: Sets the time when the power strip starts the cycle. Run duration: Can be set between 00:00 and 23:59. Off duration: Can be set between 00:00 and 23:59. 4.4 Temperature Mode If you set an outlet to Temp Mode, you’ll need to specify whether the device plugged into that outlet is for heating or cooling. For example, if it's a cooling device, the outlet will power on when the temperature exceeds your target. Heating equipment: The outlet provides power when the temperature is below the set range. Cooling equipment: The outlet provides power when the temperature is above the set range. 4.5 Humidity Mode If you set an outlet to Humi Mode, you’ll need to specify whether the device is for humidifying or dehumidifying. For example, if it's a humidifier and the humidity is too low, the outlet will power on to increase the humidity. Humidification: The outlet provides power when the humidity is below the set range. Dehumidification: The outlet provides power when the humidity is above the set range. 4.6 CO2 Mode If you set an outlet to CO2 Mode, you'll need to define whether the device is for adding CO2 or venting it out. The outlet will activate based on your CO2 target settings. Gas filling equipment: The outlet provides power when the CO2 concentration is below the set range. Air release equipment: The outlet provides power when the CO2 concentration is above the set range. 5. Settings Interface 5.1 Temperature Unit Switch between Celsius and Fahrenheit. 5.2 Environmental Set Day/Night Time Settings: Set the time range for day and night periods. The start time defines when day begins, and the start of night defines when night begins. If both day and night start times are set to the same value, the system defaults to 24 hours of day. Temp Humi CO₂Settings: Set the target temperature, humidity, and CO2 levels for both day and night, as well as the deadband range. Deadband: For example, if the daytime temperature is set to 70°F and the deadband is set to 3°F, cooling activates when the temperature reaches 73°F and stops once it drops back to 70°F. Heating activates when the temperature drops to 67°F and stops when it reaches 70°F.) 5.3 Time Set Set your local time on the controller. If the controller is linked to the Spider Farmer App, the time will sync with the device running the app. 5.4 Language Choose from multiple languages including English, German, French, Spanish, Italian, and Chinese. 5.5 Sensor Calibration Temperature Calibration: Adjust the temperature offset between -10°C and +10°C, with a precision of 0.1°C per step. Humidity Calibration: Adjust the humidity offset between -20% and +20%, with a precision of 0.1% per step. CO2 Calibration: Adjust the CO2 concentration offset between -200 ppm and +200 ppm, with a precision of 10 ppm per step. 5.6 Screen timeout Set the screen to turn off after 1-10 minutes of inactivity, or choose “Never” to keep it on. 5.7 Keytone Enable or disable the button sounds. 5.8 Firmware update Upgrade via SD card or through the network. 5.9 Factory data reset Restore the device to its original factory settings. Specs Accessory Specifications Usage Power adapter (110V-220V input, DC12V output) Used to power the dimmer Temperature and humidity sensor Working voltage:5VTemperature measurement range:-40℃~+80℃ Temperature mesurement accuracy:±0.5℃ Humidity measurement range:0-100%RH Humidity measurement accuracy:±2%RH Cable length:3 meters Used to collect environmental temperature/humidity data Dimming signal line Gray Used to connect lamps Host Silver or black, corresponding to different appearance labels according to customer needs Unified control of power supply with PWM/1-10V functional interface The kit includes: 1 x GGS controller (with power supply and a wall-mountable metal rail) 1 x GGS temperature and humidity sensor 1 x GGS 2-in-1 adapter (for connecting the lights to the controller) 2 x RJ12 telephone line splitters (for expanding connections) 2.5m RJ12 cables 6pcs (for connecting devices) 0.25m RJ12 cable 1pc (for connecting between telephone line splitters) 4 x hook and loop straps (for organizing cables) You may also want to know Recommended For Payment Shipping Warranty Feedback Return Grow tents Grow rooms Large indoor grows Vegetative growth & flowering Full-cycle growing from seedling to flowering Soil, hydroponic, aeroponic or aquaponic systems We accept eBay payment only. Please make payment within 7 days as eBay will open UNPAID case automatically. If you don't need it, please inform us within 7 days too. We ship daily Monday - Friday from US local warehouse. All orders will be shipped within one working day after payment. Shipping & Handling rate is fixed and non-refundable. If an address change is needed, you will be responsible for any fees associated in the condition that you get in touch with us after we ship your item. We only ship to eBay physical PayPal address, your eBay address should match PayPal address, PO. BOX is not acceptable. If you want to change your shipping address, please inform us at the time of purchase. Goods can be no reason to return and exchange in 30 days. If a defect arises within 1 year, Spider Farmer will provide free after-sale service. If customer return a product or part that is ineligible for service, Spider Farmer will charge customer credit card/paypal for the authorized amount. We will leave a positive feedback immediately after receiving the feedback from you. We appreciate a positive feedback as much as you do. If there is any issue with the purchase, please get in touch with us prior to leaving feedback, and we will be glad to work with you to have it resolved. Please don't give us neutral and negative feedback before get in touch with us. Don't forget that good communication can solve all problems. You will get a reply or solution within 24 hours. If there is no response after 48hrs, it should be system blocked our message, please provide us your email then we can sort the issue out for you asap. If you are not satisfied with your order, please message us. We will respond to your questions within one business day. Please do notice: (1). NO returned product will be accepted and inspected without a "Return Request" approved by SPIDER FARMER. (2). Please keep the return package intact and provide pictures to expedite refund review. If accessories (e.g. wires, controllers, hangers) are missing, the product cannot be returned or exchanged.
Price: 89.99 USD
Location: Perth Amboy, New Jersey
End Time: 2024-11-10T04:06:44.000Z
Shipping Cost: 0 USD
Product Images
Item Specifics
Restocking Fee: No
Return shipping will be paid by: Seller
All returns accepted: Returns Accepted
Item must be returned within: 30 Days
Refund will be given as: Money back or replacement (buyer's choice)
Brand: Spider Farmer
Model: SF-GGS-Controller Kits
Type: Controller
Color: Black
Application: LED Grow Light
Features: Adjustable Humidity Control, Automatic Shut Off, Digital Display, LED Display, Timer, Wired, Remote Control
Humidification Method: NO
Manufacturer Warranty: 2 Years
Timer Control: 24 hrs
Power Source: Electrical
Country/Region of Manufacture: China